2125 196th St SW
Suite 115
Lynnwood, WA
98036
Phone: 425-774-3257

   Attn:
    Government Buyers

DUNS Number
362928293

CAGE Code
3ZDG4

Registered with
 CCR

    NAICS Code 333411
FSC Code 4460
SIC Code 3564

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OmniAire Omniforce II

negative air machine

Modular style negative air machine used in mold abatement, asbestos abatement, and lead abatement projects. Easily transported in two pieces, each weighing under 75 pounds. Available accessories include UV germicidal irradiation modules and activated carbon filters for removal of chemical fumes and biological contaminants. This equipment provides a cleaner and healthier environment in industrial facilities as well as abatement projects.

SPECIFICATIONS

Airflow - 200-1900 cfm 
    
Airflows are based on blower manufacturer curves. Different HEPA filters may cause the
     flow to vary.  
Weight -
95 lbs with filter attached
Dimensions - 18" wide 27" high 32" long with filter attached
Filtration -
     Primary/Secondary Filter - D
ual-ply Dustlok polyester pad
     Standard HEPA Filter - Metal Frame 99.97% Efficiency .3 micron
     Optional - Carbon Filter for odor control
Power Requirement - 115 VAC/ 50-60 Hz 12.0 amps
Cabinet -
     Aircraft grade aluminum, closed end rivet construction. All seams are silicone sealed
     before riveting. 4 hospital grade non-marking 3" casters for ease of movement.
Controls -
     Speed Selector Switch - HIGH/SPEED CONTROL
     Variable Speed Controller
     Pressure Gauge - 0" to 5"
Outlet Ring Size
- 14" diameter       

                            Ordering Information

ITEM                                                                               PART #

OmniAire Omniforce II Negative Air Machine                OF100V

HEPA Filter, Metal Frame 99.97%, 0.3µ                         OFH12

Bag Filter Housing                                                          HBF100X

Bag Filter 95% ASHRAE                                                 OBF9

Primary/Secondary Filter (qty 20)                               OFP2518

Intake Manifold, 14”                                                      OFM14

Quick Clamp, 14”                                                            QC14

Flexible Duct, 14”x25’                                                    OFD14

OdorGuard 600 Carbon Filter                                        OG2116

OdorGuard 750 Plus Carbon Filter                                OGP2116

Carbon Vapor Trap Filter                                              OCVT18

UV Germicidal Irradiation Module                                 UVCM100X

                        Printer Friendly Specification Sheet